HP (Hewlett-Packard) 79XXY Personal Computer User Manual


 
upgrading and servicing the pc
31
Filename: ma1rwtc.doc Title: HP-Print2k.dot
Template: HP-Print2K.dot Author: WASSER, Inc. Last Saved By: WASSER, Inc.
Revision #: 161 Page: 31 of 46 Printed: 04/26/01 09:20 AM
English
Initialization
Many communications programs react to the default settings
when started. This is usually achieved by the ATZ command
and initializes your modem for correct operation. Many
programs are developed for worldwide use and generally
use the ATZ command; however, some programs have built-
in modem configuration utilities and these should not be
used unless you can confirm that they are compatible with
Australian and New Zealand requirements.
If your program does not use the ATZ command to initialize,
but instead sends a complex string of characters, then it must
be configured to send the correct string for Australia and
New Zealand. The correct initialization string is (spaces
should not be entered; they are to make it easier to read):
AT &F T /N6 S6=3 S7=45 % L=7 &Y0 &W0
Once you have entered this command string, it is written to
the internal memory of the modem and the default
configuration.
Dialing
The modem supports both pulse and tone dialing in
Australia and only tone dialing in New Zealand. New
Zealand users please note that if pulse dialing is selected,
then wrong numbers will be dialed, as the reverse
numbering scheme is not supported. There are several dial
string modifiers referred to in the main users manual, and
we suggest that they be used with caution to avoid problems
when making calls.
Automatic Answering
To conform with Austel and Telecom New Zealand
requirements when configuring your modem for auto-
answering, please do not set the SO register to values less
than 2 or greater than 10 (Note: ATSO-O will disable auto-
answering). Pre-configured software should be checked and
changed as necessary. These settings ensure:
3
A person calling your modem will hear a short burst of
ringing before the modem answers. This confirms that the
call has been successfully switched through the network.
3
Caller identification information (which occurs between
the first and second ring cadences) is not destroyed.
Automatic Multiple Dialing Attempts
Most communication software can be configured to make
automatic dialing attempts to a telephone number that is
busy or not answering (automatic redial function). The
maximum number of all attempts that can be made in one
sequence must not exceed the numbers shown in the
following table. If your program makes continuous automatic
dialing attempts or more than the number in the table, and it
cannot be changed, an alternative program must be used or
automatic dialing disabled. There is no limit for manually
initiated dialing attempts.