HP (Hewlett-Packard) BL30p Server User Manual


 
Operating and
Performance
Specifications for ProLiant
BL p-Class GbE2
Interconnect Switch
Dimensions
Height
10.405 in (26.43 cm)
Width
1.535 in (3.899 cm)
Depth
27.697 in (70.35 cm)
Weight
12.0 lb/5.4 kg per interconnect switch
Performance
24 Gbps External port bandwidth per server blade enclosure (full duplex)
Forwarding rate 1.5 million pps per gigabit port (64-byte packets)
Auto-MDI/MDIX, auto-negotiation and auto-sensing with full-duplex support
Forwarding Mode
Store and forward
MAC Addresses
2,048 per interconnect switch
Forwarding Table
Age Time
Maximum age: 1 to 65535 seconds; default: 300 seconds
Memory
128MB Main, 32MB flash and 2MB packet buffer per interconnect switch
Compliance
IEEE 802.3, 802.3u, 802.3ab, 802.3x, 802.3z (F-GbE2 only), 802.1D, 802.3ac, 802.3ad
(Static), and 802.1Q
SNMP v1 (RFC 1157), MIB-II (RFC 1213), Bridge MIB (RFC 1493), Interface Group MIB
(RFC 2863), Ethernet MIB (RFC 1643), 802.1Q Extended Bridge MIB , Entity MIB (RFC
2037), RADIUS Authentication MIB, 802.3-2002 MIB, SNMP Trap Convention (RFC
1215), Bridge Trap (RFC 1493), Remote Monitoring Traps (RFC 1757) and HP
Enterprise Switch MIBs and Environmental Traps
RADIUS (RFC 2138), Telnet (RFC 854), TFTP client (RFC 783), SSH v1.5, SCP v1.5,
NTP v2 (RFC 1119), BootP client (RFC 2132), and XModem
Network Transfer
Rate
10 Base-T (half-duplex)
10 Mbps
10 Base-T (full-duplex)
20 Mbps
100 Base-TX (half-duplex)
100 Mbps
100 Base-TX (full-duplex)
200 Mbps
1000 Base-TX (half-duplex)
1000 Mbps
1000 Base-TX (full-duplex)
2000 Mbps
1000 Base-SX (full-duplex)
2000 Mbps
Connector
12 RJ-45, 2 DB-9 (C-GbE2 Interconnect Kit)
8 LC fiber, 4 RJ-45, 2 DB-9 (F-GbE2 Interconnect Kit)
EMI
FCC Class A
ICES-003 Class A
AS/NZS 3548 Class A
VCCI Class A
Safety
UL/CUL Listed Accessory
CE
Power
Requirements
48VDC: 2040 mA, 98 W maximum (per interconnect switch without GbE2 Storage
Connectivity Kit)
48VDC: 2355 mA, 113 W maximum (per interconnect switch with GbE2 Storage
Connectivity Kit)
Temperature
Range
Operating
50° to 95° F (10° to 35° C)
Non-operating
-22° to 140° F (-30° to 60° C)
Relative Humidity
(non-condensing)
Operating
20% to 80%
Non-operating
5% to 95%
Wet Bulb
Temperature
Operating
82.4° F (28° C)
Non-operating
101.7° F (38.7° C)
NOTE:
Operating temperature has an altitude derating of 34° F/1° C per 1,000 ft/304.8 m. No direct sunlight. Upper
operating limit is 10,000 ft/3,048 m or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft/9,144 m or 30.3 KPa/4.4
psia. Storage maximum humidity of 95% is based on a maximum temperature of 113° F/45° C. Altitude maximum for
storage is 70 KPa.
QuickSpecs
HP ProLiant BL30p Server Blade
Technical Specifications
DA - 11958 North America — Version 6 — September 24, 2004