HP (Hewlett-Packard) DC7800 Personal Computer User Manual


 
Unit Environment and
Unit Environment andUnit Environment and
Unit Environment and
Operating Conditions
Operating ConditionsOperating Conditions
Operating Conditions
Ultra-slim Desktop
Ultra-slim DesktopUltra-slim Desktop
Ultra-slim Desktop
Small Form Factor
Small Form FactorSmall Form Factor
Small Form Factor
Convertible Minitower
Convertible MinitowerConvertible Minitower
Convertible Minitower
General Unit Operating Guidelines
Keep the computer away from excessive moisture, direct moisture and the extremes of heat and cold, to ensure that unit is
operated within the specified operating range.
Leave a 10.2 cm (4 in) clearance on all vented sides of the computer to permit the required airflow.
Never restrict airflow into the computer by blocking any vents or air intakes.
Do not stack computers on top of each other or place computers so near each other that they are subject to each other's re-
circulated or preheated air.
Occasionally clean the air vents on the front, back, and any other vented side of the computer. Lint, dust and other foreign
matter can block the vents and limit the airflow.
If the computer is to be operated within a separate enclosure, intake and exhaust ventilation must be provided on the
enclosure, and the same operating guidelines listed above will still apply.
Temperature Range
Operating: 50° to 95° F (10° to 35° C)*
Non-operating: -22° to 140° F(-30° to 60° C)
Relative Humidity
Operating: 10% to 90% (non-condensing at ambient)
Non-operating: 5% to 95% (non-condensing at ambient)
Maximum Altitude
(unpressurized)
Operating: 10,000 ft (3048 m)
Non-operating: 30,000 ft (9144 m)
*
Operating temperature is de-rated 1.0 deg C per 300 m (1000 ft) to 3000 m (10,000 ft) above sea level, no direct sustained
sunlight. Maximum rate of change is 10 deg C/Hr. The upper limit may be limited by the type and number of options installed.
Power Supply
Power SupplyPower Supply
Power Supply
Ultra-slim Desktop
Ultra-slim DesktopUltra-slim Desktop
Ultra-slim Desktop
Small Form Factor
Small Form FactorSmall Form Factor
Small Form Factor
Convertible Minitower
Convertible MinitowerConvertible Minitower
Convertible Minitower
Power Supply
135W external power supply, 85%
efficient, active PFC
240W power supply, active PFC 365W power supply, active PFC
Operating Voltage Range
90 – 264 VAC 90 – 264 VAC 90 – 264 VAC
Rated Voltage Range
100 – 240 VAC 100 – 240 VAC 100 – 240 VAC
Rated Line Frequency
50/60 Hz 50/60 Hz 50/60 Hz
Operating Line Frequency
Range
47 – 63 Hz 47 – 63 Hz 47 – 63 Hz
Rated Input Current
N/A
4A 6A
Rated Input Current with
Energy Efficient* Power
Supply
1.5A 3.5A
5A
Current Leakage
(NFPA 99)
< 275 µA < 275 µA < 450 µA
System Heat Dissipation
N/A
Typical 198 btu/hr
(50 kg-cal/hr)
Maximum 1260 btu/hr
(318 kg-cal/hr
Typical 222 btu/hr
(56 kg-cal/hr)
Maximum 1916 btu/hr
(483 kg-cal/hr)
System Heat Dissipation
with Energy Efficient* Power
Supply
Typical 133 btu/hr
(33.5 kg-cal/hr)
Maximum 549 btu/hr
(132 kg-cal/hr)
Typical 150 btu/hr
(38 kg-cal/hr)
Maximum 1024 btu/hr
(258 kg-cal/hr)
Typical 171 btu/hr
(43 kg-cal/hr)
Maximum 1557 btu/hr
(392 kg-cal/hr)
Power Supply Fan
N/A
80mm variable speed 92mm variable speed
QuickSpecs
HP Compaq dc7800 Business PC
HP Compaq dc7800 Business PCHP Compaq dc7800 Business PC
HP Compaq dc7800 Business PC
Technical Specifications
DA - 12744 North America — Version 25 — May 16, 2008
Page 23