HP (Hewlett-Packard) DL360 Server User Manual


 
Server component identification 17
System LED
and color
Internal
Health LED
color
Status
Processor
failure, both
sockets
(Amber)
Red Processor types are mismatched.
PPM failure
(Amber)
Red PPM has failed.
DIMM failure,
slot X (Amber)
Red • DIMM in slot X has failed.
DIMM in slot X is an unsupported type, and no valid memory
exists in another bank.
Amber • DIMM in slot X has reached single-bit correctable error
threshold.
DIMM in slot X is in a pre-failure condition.
DIMM in slot X is an unsupported type, but valid memory exists
in another bank.
DIMM failure, all
slots in one
bank (Amber)
Red No valid or usable memory is installed in the system.
Overtemperatur
e (Amber)
Amber The health driver has detected a cautionary temperature level.
Red The server has detected a hardware critical temperature level.
Riser interlock
(Amber)
Red The PCI riser board assembly is not seated.
Online spare
memory
(Amber)
Amber Bank X failed over to the online spare memory bank.
Power
converter
module
interlock
(Amber)
Red The power converter module is not seated.
Fan module
(Amber)
Amber A redundant fan has failed.
Fan module
(Red)
Red The minimum fan requirements are not being met in one or more
of the fan modules. One or more fans have failed or are missing.