HP (Hewlett-Packard) dx7300 Personal Computer User Manual


 
QuickSpecs
HP Compaq dx7300 Business PC
Technical Specifications
DA – 12583 EMEA Version 1 • September 18, 2006 Page 13
Unit Environment and Operating Conditions
General Unit Operating Guidelines
Keep the computer away from excessive moisture, direct moisture and the extremes of heat and cold, to ensure that unit
is operated within the specified operating range.
Leave a 10.2 cm (4 in) clearance on all vented sides of the computer to permit the required airflow.
Never restrict airflow into the computer by blocking any vents or air intakes.
Do not stack computers on top of each other or place computers so near each other that they are subject to each other's
re-circulated or preheated air.
Occasionally clean the air vents on the front, back, and any other vented side of the computer. Lint, dust and other
foreign matter can block the vents and limit the airflow.
If the computer is to be operated within a separate enclosure, intake and exhaust ventilation must be provided on the
enclosure, and the same operating guidelines listed above will still apply.
Temperature Range Operating: 50° to 95° F (10° to 35° C)*
Non-operating: -22° to 140° F(-30° to 60° C)
Relative Humidity Operating: 10% to 90% (non-condensing at ambient)
Non-operating: 5% to 95% (non-condensing at ambient)
Maximum Altitude (unpressurized) Operating: 10,000 ft (3048 m)
Non-operating: 30,000 ft (9144 m)
*NOTE: Operating temperature is de-rated 1.0 deg C per 300 m (1000 ft) to 3000 m (10,000 ft) above sea level, no direct
sustained sunlight. Maximum rate of change is 10 deg C/Hr. The upper limit may be limited by the type and number of options
installed.
Power Supply Microtower
Power Supply 365 watt custom power supply Active PFC
Operating Voltage Range 90 – 264 VAC
Rated Voltage Range 100 – 240 VAC
Rated Line Frequency 50/60 Hz
Operating Line Frequency Range 47 – 63 Hz
Rated Input Current 6A
System Heat Dissipation Typical 375 btu/hr
(95 kg-cal/hr)
Maximum 1916 btu/hr
(483 kg-cal/hr)
Power Supply Fan 92mm variable speed
Energy Star Compliant YES
Blue Angel Compliant
(<5w in S5 – Power Off)
YES
FEMP Standby Power Compliant
(<2W in S5 – Power Off)**
YES
Power Consumption in ES Mode –
Suspend to RAM (S3) (Instantly Available
PC)
< 3W