HP (Hewlett-Packard) HP-UX 11i Server User Manual


 
They range from a 64-way Superdome with dual cord and dual UPS with main tie main to a 32-way Superdome with single
cord and single UPS. In all configurations the APC Silcon SL20KFB2 has been tested and qualified by the Superdome
engineers to ensure interoperability.
HP UPS Solutions
HP UPS SolutionsHP UPS Solutions
HP UPS Solutions
Product
ProductProduct
Product
Number/
Number/Number/
Number/
Description
DescriptionDescription
Description
Quantity/
Quantity/Quantity/
Quantity/
Configuration
ConfigurationConfiguration
Configuration
Watt
WattWatt
Watt
VA
VAVA
VA
Technology
TechnologyTechnology
Technology
Family
FamilyFamily
Family
Package
PackagePackage
Package
Output
OutputOutput
Output
SL20KFB2
APC Silcon
3-phase UPS
Quantity 2/
32- or 64-way
dual-cord/dual-
UPS with main-
tie-main
Quantity 1/
32- or 64-way
single-cord/
single-UPS
20 kW
20 kVA
Delta
conversion
on line
double
conversion
APC
Silcon
3-phase
Standalone
rack
Configurable
for 200: 208
or 220V 3
phase
nominal
output
voltage
QJB22830
Switch Gear
Quantity 1/
32- or 64-way
dual- cord/dual-
UPS with main-
tie-main
Quantity 0/
32- or 64-way
single- cord/
single-UPS
N/A N/A N/A
Customer
Design for
Superdome
N/A N/A
WSTRUP5X8- SL10
Start Up Service
Quantity 2/
32- or 64-way
dual-cord/dual-
UPS with main-
tie-main
Quantity 1/
32- or 64-way
single-cord/
single-UPS
N/A N/A N/A N/A N/A N/A
WONSITENBD-
SL10
Next Business Day
On site Service
Quantity 2/
32- or 64-way
dual- cord/dual-
UPS with main-
tie-main
Quantity 1/
32- or 64-way
single- cord/
single-UPS
N/A N/A N/A N/A N/A N/A
Power Protection
Power ProtectionPower Protection
Power Protection
Runtimes
RuntimesRuntimes
Runtimes
The UPS will provide battery backup to allow for a graceful shutdown in the event of a power failure. Typical runtime on the
APC SL20KFB2 Silcon 3 Phase UPS varies with the kW rating and the load. The APC SL20KFB2 UPS provides a typical
runtime of 36.7 minutes at half load and 10.7 at full load. If additional run time is needed please contact your APC
representative
Power Conditioning
Power ConditioningPower Conditioning
Power Conditioning
The APC SL20KFB2 provides unparalleled power conditioning with its Delta-Conversion on- line double conversion
technology. This is especially helpful in regions were power is unstable.
Continuous Power during Short Interruptions of Input Power
Continuous Power during Short Interruptions of Input PowerContinuous Power during Short Interruptions of Input Power
Continuous Power during Short Interruptions of Input Power
The APC SL20KFB2 will provide battery backup to allow for continuous power to the connected equipment in the event of a
brief interruption in the input power to the UPS. Transaction activity will continue during brief power outage periods as long
as qualified UPS units are used to provide backup power to the SPU, the Expansion Modules, and all disk and disk array
products.
QuickSpecs
HP Integrity Superdome Servers: 16-way, 32-way,
HP Integrity Superdome Servers: 16-way, 32-way,HP Integrity Superdome Servers: 16-way, 32-way,
HP Integrity Superdome Servers: 16-way, 32-way,
and 64-way
and 64-wayand 64-way
and 64-way
Configuration
DA - 11717 Worldwide — Version 2 — July 15, 2003
Page 19