System Unit - Rack
Dimensions
(HxWxD)
8.61 x 19 x 24 in (21.87 x 48.26 x 60.96 cm)
Weight
(approximate)
60 lb (27.24 kg) (without hard drives)
Input Requirements
(per power supply)
Rated Line Voltage
100 to 120 VAC
Rated Input Frequency
50 Hz to 60 Hz
Input Power
906W @ 100VAC
Rated Input Current
9.2A(100VAC), 4.3A(200VAC)
Rated Line Frequency
50 to 60 Hz
BTU Rating
3,125 BTU/hr
SCSI Connectors
Two internal HD68 connectors
NOTE:
Support for either two internal, two external, or a mix of
internal/external is available. This is achieved using an internal to
external SCSI cable option kit, PN 159547-B22 or 333370-B21, and
either of the two SCSI knockouts.
Power Supply Output
Power
(per power supply)
Rated Steady-State
Power
725W
Temperature Range
Operating
50° to 95° F (10° to 35° C)
(No direct sustaining sunlight)
Storage (up to one year)
-40° to 158° F (-40° to 70° C)
Maximum Wet Bulb
Temperature
82.4° F (28° C)
Relative Humidity
(non-condensing)
Operating
10% to 90%
Non-operating
5% to 90%
Acoustic Noise
Idle
(Fixed Disk Drives
Spinning)
L
WAd (BELS)
6.0
L
pAm (dBA)
43
Operating
(Random Seeks to Fixed
Disks)
L
WAd (BELS)
6.0
L
pAm (dBA)
43
QuickSpecs
HP ProLiant ML350 Generation 4p
Technical Specifications
DA - 12199 Worldwide QuickSpecs — Version 29 — 11.14.2006
Page 43