HP (Hewlett-Packard) ML350 Webcam User Manual


 
System performance may be reduced if
operating with a fan fault or above 30°C
(86°F).
Non-operating
-30° to 60°C (-22° to 140°F). Maximum rate of
change is 20°C/hr (36°F/hr).
Relative Humidity
(non-condensing)
Operating
10 to 90% relative humidity (Rh), 28°C
(82.4°F) maximum wet bulb temperature, non-
condensing.
Non-operating
5 to 95% relative humidity (Rh), 38.7°C
(101.7°F) maximum wet bulb temperature,
non-condensing.
Altitude
Operating
3050 m (10,000 ft). This value may be limited
by the type and number of options installed.
Maximum allowable altitude change rate is
457 m/min (1500 ft/min).
Non-operating
9144 m (30,000 ft). Maximum allowable
altitude change rate is 457 m/min (1500
ft/min).
Acoustic Noise
Listed are the declared A-Weighted sound power levels (LWAd) and
declared average bystander position A-Weighted sound pressure levels
(LpAm) when the product is operating in a 23°C ambient environment.
Noise emissions were measured in accordance with ISO 7779 (ECMA
74) and declared in accordance with ISO 9296 (ECMA 109).
Idle
L
WAd
5.2 B
L
pAm
35 dBA
Operating
L
WAd
5.3 B
L
pAm
35 dBA
Emissions
Classification
(EMC)
FCC Rating
Class B
Normative Standards
CISPR 22; EN55022; EN55024; FCC CFR 47,
Pt 15; ICES-003; CNS13438; GB9254;
K22;K24; EN 61000-3-2; EN 61000-3-3; EN
60950-1; IEC 60950-1
NOTE:
Product conformance to cited product specifications is based on
sample (type) testing, evaluation, or assessment. This product or family
of products is eligible to bear the appropriate compliance logos and
statements.
QuickSpecs
HP ProLiant ML350 Generation 5
Technical Specifications
DA - 12475 Worldwide QuickSpecs — Version 44 — 4.27.2009
Page 45