HP (Hewlett-Packard) PA-8600 Server User Manual


 
Pre-existing SMS
Pre-existing SMSPre-existing SMS
Pre-existing SMS
Customers
CustomersCustomers
Customers
Some customers may have an existing rp2470 or A500 SMS that required a separate console device. Typically a Unix
workstation or PC was configured in these environments. These customers may continue to use their existing SMS (with the
appropriate software upgrade) along with their existing console device to access the new PA-8800 Superdome. A
Superdome console must meet the following requirements:
HP Workstation running HP-UX 11.0 or 11i v1
PC running Windows NT, XP, 2000
C1099A terminal server (limited functionality due to text mode only operation)
10Base-T Ethernet connection or an RS-232 port or both.
X windows emulator for console access on the PC (i.e., Reflection for HP with NS/VT).
Option 006 and 007 Specifics
Option 006 and 007 SpecificsOption 006 and 007 Specifics
Option 006 and 007 Specifics
a
Customer-Provided Part
Customer-Provided PartCustomer-Provided Part
Customer-Provided Part
PDCA Product Number
PDCA Product NumberPDCA Product Number
PDCA Product Number
Attached Power Cord
Attached Power CordAttached Power Cord
Attached Power Cord
Attached Plug
Attached PlugAttached Plug
Attached Plug
In-Line Connector
In-Line ConnectorIn-Line Connector
In-Line Connector
Panel-Mount Receptacle
Panel-Mount ReceptaclePanel-Mount Receptacle
Panel-Mount Receptacle
A5800A Option 006
OLFLEX 190 (PN 600804),
four conductor, 6-AWG (16-
mm
2
), 600-Volt, 60-Amp, 90-
degree C, UL, and CSA
approved, conforms to CE
directives GN/YW ground
wire.
Mennekes ME 460P9 3-phase,
4-wire, 60-Amp, 250-Volt, UL
approved. Color blue, IEC
309-1, IEC 309-1, grounded
at 3:00
Mennekes ME 460C9 3-
phase, 4-wire, 60-amp, 250-
Volt, UL approved. Color
blue, IEC 309-1, IEC 309-1,
grounded at 9:00.
a
Mennekes ME 460R9 3-phase,
4-wire, 60-amp, 250-Volt, UL
approved. Color blue, IEC
309-1, IEC 309-1, grounded
at 9:00.
b
A5800A Option 007
Five conductors, 10-AWG (6-
mm
2
), 450/475-Volt, 32-
Amp, <HAR> European wire
cordage, GN/YW ground wire.
Mennekes ME 532P6-14 3-
phase, 5-wire, 32-Amp,
450/475-volt, VDE certified,
color red, IEC 309-1, IEC
309- 2, grounded at 6:00.
Mennekes ME 532C6-16 3-
phase, 5-wire, 32-Amp,
450/475-Volt, VDE certified,
color red, IEC 309-1, IEC
309-2, grounded at 6:00.
c
Mennekes ME532R6-1276 3-
phase, 5-wire, 32-Amp,
450/475-Volt, VDE certified,
color red, IEC 309-1, IEC
309-2, grounded at 6:00.
b
a. In-line connector is available from HP by purchasing A6440A, Option 401.
b. Panel-mount receptacles must be purchased by the customer from a local Mennekes supplier.
c. In-line connector is available from HP by purchasing A6440A, Option 501.
NOTE:
NOTE: NOTE:
NOTE:
A qualified electrician must wire the PDCA in-line connector to site power using copper wire and in compliance with all local codes.
Input Requirements
Input RequirementsInput Requirements
Input Requirements
Reference the Site Preparation Guide for detailed power configuration requirements.
Requirements
RequirementsRequirements
Requirements
Value
ValueValue
Value
Conditions/Comments
Conditions/CommentsConditions/Comments
Conditions/Comments
Nominal Input Voltage (VAC rms)
200/208/220/230/240
Input Voltage Range (VAC rms)
200-240
Auto selecting. Measure at input terminals.
Frequency Range (Hz)
50/60
Number of Phases
3
3-phase 5-wire with power cord;
3-phase 4-wire with power cord
Maximum Input Current (A rms), 3-Phase 5-wire
20
3-phase source with a source voltage of 220 VAC
measured phase to neutral
Maximum Input Current (A rms), 3-Phase 4-wire
40
3-phase source with a source voltage of either 208
VAC or 230 VAC measured phase-to-phase
Maximum Inrush Current (A peak)
90
Circuit Breaker Rating (A), 3-Phase 5-wire
25 A
Per phase
Circuit Breaker Rating (A), 3-Phase 4-wire
45 A
Per phase
Power Factor Correction
0.95 minimum
Ground Leakage Current (mA)
>3.5 mA, with 6 BPSs installed
Warning label applied to the PDCA at the AC
Mains input
QuickSpecs
HP 9000 Superdome Servers
HP 9000 Superdome ServersHP 9000 Superdome Servers
HP 9000 Superdome Servers
(PA-8600, PA-8700 and PA-8800)
(PA-8600, PA-8700 and PA-8800)(PA-8600, PA-8700 and PA-8800)
(PA-8600, PA-8700 and PA-8800)
System Management Features
DA - 11721 North America — Version 13 — April 1, 2005
Page 22