HP (Hewlett-Packard) PA 8700 Server User Manual


 
HP-UX Attributes
HP-UX AttributesHP-UX Attributes
HP-UX Attributes
Maximum CPUs per HP-UX 11i
partition
16 32 64
Maximum CPUs per HP-UX 11i
partition
16 32 128
Maximum memory per HP-UX
11i partition
128 GB 256 GB 512 GB
Maximum memory per HP-UX
11i partition
128 GB 256 GB
1 TB
HP-UX revisions supported
HP-UX 11i, HP-UX 11i v2 HP-UX 11i, HP-UX 11i v2
HP-UX 11i, HP-UX 11i
v2
Maximum I/O Cards See supported I/O table for specific products
Maximum I/O Cards See supported I/O table for specific productsMaximum I/O Cards See supported I/O table for specific products
Maximum I/O Cards See supported I/O table for specific products
Mass Storage
16 - 48 32 - 96
64 - 192
LAN
8 - 24
16 - 48 32 - 96
WAN
8 - 25
16 -25 25 -32
Multi-Function (Mass Storage /
LAN)
8 - 16
16 -32 32 -64
Additional Interface Cards
8
8 -16 8 -32
Electrical Characteristics
Electrical CharacteristicsElectrical Characteristics
Electrical Characteristics
AC input power-Option 7: 3-
phase 5-wire input
200-240 VAC phase-to-neutral, 5-wire, 50/60 Hz
AC input power-Option 6: 3-
phase 4-wire input
200-240 VAC phase-to-phase, 4-wire, 50/60 Hz
Maximum Current requirements
at 220V 240V:
Option 7:
3-phase 5-wire input
24 A/Phase
Option 6:
3-phase 4-wire input
44 A/Phase
Required Power Receptacle-
Options 6 and 7
None. Cord, plug and included. Receptacle should be ordered separately. Electrician must
hard wire receptacle to site power.
Site Preparation
Site PreparationSite Preparation
Site Preparation
Site planning and installation
included
Yes Yes Yes
Depth (mm / inches)
1,220 / 48.1 1,220 / 48.1 1,220 / 48.1
Width (mm / inches)
762 / 30 762 / 30
1,524 / 60
Height (mm / inches)
1,960 / 77.2 1,960 / 77.2 1,960 / 77.2
Weight (Kg / lbs)
500 / 1,123 598 / 1,343
1,196 / 2,685
Environmental Characteristics
Environmental CharacteristicsEnvironmental Characteristics
Environmental Characteristics
Acoustics
65 dB
Operating temperature
68° to 86° F (20° to 30° C)
Non-operating temperature
-40° to 158° F (-40° to 70° C)
Maximum rate of temperature
change
68° F/hr (20° C/hr)
Operating relative humidity
15% to 80% @ 86° F (30° C)
Operating altitude
0 to 10,000 ft (0 to 3.1 km)
Non-operating altitude
0 to 15,000 ft (0 to 4.6 km)
QuickSpecs
HP 9000 Superdome Servers
HP 9000 Superdome ServersHP 9000 Superdome Servers
HP 9000 Superdome Servers
(PA-8600, PA-8700 and PA-8800)
(PA-8600, PA-8700 and PA-8800)(PA-8600, PA-8700 and PA-8800)
(PA-8600, PA-8700 and PA-8800)
Technical Specifications
DA - 11721 North America — Version 13 — April 1, 2005
Page 36