HP (Hewlett-Packard) DL585 Network Card User Manual


 
System Unit Rack
System Unit RackSystem Unit Rack
System Unit Rack
Chassis Footprint
Chassis FootprintChassis Footprint
Chassis Footprint
(HxWxD)
6.94 x 19 x 26.5 in (17.6 x 48.3 x 67.3 cm)
Weight
WeightWeight
Weight
No hard drives installed,
one power supply
66 lb (29.9 kg)
Input Requirements
Input RequirementsInput Requirements
Input Requirements
Rated Input Voltage
100 to 120 VAC/200 to 240 VAC
Rated Input Frequency
50 to 60 Hz
Input Power
1135W @ 110 VAC/1125W @ 220 VAC
Rated Input Current
12A (100 VAC), 9.8A (120 VAC), 4.9A (220
VAC)
Max BTU Rating
Max BTU RatingMax BTU Rating
Max BTU Rating
4000 BTU
Power Specifications
Power SpecificationsPower Specifications
Power Specifications
To review typical system power ratings use the Active Answers Power
Calculator which is available via the online tool located at URL:
http://h30099.www3.hp.com/configurator/powercalcs.asp
.
To drill down to calculators:
Click on: "ProLiant Servers"
Click on the Server of interest. Example: DL585
Click on: "Power Calculator" link (You may need to scroll down to see
it.)
Power Supply Output
Power Supply OutputPower Supply Output
Power Supply Output
Power
PowerPower
Power
(per power supply)
Rated Steady-State Power
800W/800W (lowline/highline)
Maximum Peak Power
800W/800W (lowline/highline)
Temperature Range
Temperature RangeTemperature Range
Temperature Range
Operating
50° to 95° F (10° to 35° C)
Non-operating
-20° to 140° F (-29° to 60° C)
Shipping
-22° to 122° F (-30° to 50° C)
Relative Humidity
Relative HumidityRelative Humidity
Relative Humidity
(non-condensing)
Operating
10% to 70%
Non-operating
5% to 95%
Maximum Wet Bulb
Maximum Wet BulbMaximum Wet Bulb
Maximum Wet Bulb
Temperature
TemperatureTemperature
Temperature
101.7° F (38.7° C)
Acoustic Noise
Acoustic NoiseAcoustic Noise
Acoustic Noise
NOTE:
NOTE:NOTE:
NOTE:
Listed are the declared A-weighted sound power levels LWAd and the
declared average bystander position sound pressure levels LpAm when
operating in a 23° C ambient environment. Noise emissions were measured
in accordance with ECMA 74 and declared in accordance with ECMA 109.
Idle (Fixed Disk Drives
Spinning)
L
LL
L
WAd (BELS)
7.3
L
L L
L
pAm (dBA)
55
Operating Minimum
(Random Seeks to Fixed
Disks)
L
L L
L
WAd (BELS)
7.3
L
LL
L
pAm (dBA)
55
NOTE:
NOTE: NOTE:
NOTE:
These values apply to 4U rack configuration with the Health Driver
Fan Control active. Configuration tested included 2 AMD Opteron 2.2 GHz
processors, 1 15 krpm hard drive, 2 power supplies, 4 memory/IO fans and
4 CPU fans.
QuickSpecs
HP ProLiant DL585
HP ProLiant DL585HP ProLiant DL585
HP ProLiant DL585
Technical Specifications
DA - 11902 Worldwide — Version 29 — May 5, 2005
Page 40