HP (Hewlett-Packard) SA3150 Server User Manual


 
Hewlett-Packard VPN Server Appliance SA3150 Regulatory Information 7
Reliable earthing (grounding) of the unit should be
maintained. Particular attention should be given to supply
connection other than direct connections to the branch
circuit (such as power strips).
CAUTION: Ensure that a reliable earth ground is provided
for the rack.
Cabling Requirements
The HP VPN Server Appliance SA3150 is shipped with a
power cable and a DB-9 admin cable. The power cable is
6.5 feet (198 centimeters) in length, and the DB-9 Admin
cable is 65 inches in length (160 centimeters). Use the
following information to plan for the additional cables that
you need.
The HP VPN Server Appliance SA3150 also comes with two
ferrite bead cables that attach to your 10BaseT/100BaseTX
Ethernet connection.
Ethernet Cable Requirements
The HP VPN Server Appliance SA3150 supports twisted-
pair 10BaseT/100BaseTX Ethernet connections. Category
5 or better, 26 AWG cable must be used.
Safety Precautions
WARNING: Turn the power off, disconnect the power
cable, and disconnect all other cables before you perform
this procedure. Do not reattach any cables until you
replace the cover of the unit chassis and tighten the cover
screws on the chassis.
CAUTION: Attach the disposable grounding wrist strap to
your wrist and an exposed portion of the HP VPN device
chassis as indicated in the instructions on the wrist strap
packaging.