HP (Hewlett-Packard) XP48 Network Router User Manual


 
50 HP StorageWorks Disk Array XP Operating System Configuration Guide: HP-UX
Error conditions
Depending on your system configuration, you may be able to view error
messages as follows:
View SIMs in Command View (Device Health tab).
View R-SIMs in Remote Control XP, including reference codes and
severity levels of recent R-SIMs.
View SIMs that generate SNMP traps on the host.
Error Condition Recommended Action
The logical devices are not
recognized by the host.
Verify that the READY indicator lights on the disk array are ON.
Verify that fiber cables are correctly installed and firmly connected.
Verify that the target IDs are properly configured. The LUNs for each
TID must start at 0 and continue sequentially without skipping any
numbers.
Verify that the TIDs/WWNs on each bus are unique. Do not install
two devices with the same ID on the same bus.
Recheck the buses for new devices.
Verify that LUSE devices are not intermixed with normal LUNs on the
same port.
Verify that the maximum number of LUSE devices per port has not
been exceeded.
Verify that the disk array Host Mode is set correctly.
The host does not reboot
properly after hard shutdown.
If you power off the host without executing the shutdown process,
wait three minutes to allow the disk array’s internal timeout process to
purge queued commands. If the host restarts while the disk array is
processing queued commands, the host may not reboot successfully.