TROUBLESHOOTING
Make the checks suggested below depending on the symptoms observed. If the
symptoms remain uncorrected, contact your dealer.
Symptoms That Seemingly Appear to be Failures
• Customer servicing can be hazardous.
WARNING
Symptom Point to check
See
page
• No picture with the power-
indicating lamp off.
• Check the way the power cable is connected.
• Press the power switch.
• The message “POWER
SAVE” is displayed.
• No picture with the power
indicating lamp flickering in
green.
POWER SAVE
No sync signal is detected.
• Check the way the signal cable is connected.
• Make sure that the switch of the computer,
imaging equipment , etc., is turned on.
• Make sure the computer is not in the power-save
mode.
• Check to see if the input selection matches the
connection terminal.
• The message “OUT OF
FREQUENCY” is displayed.
OUT OF FRQUENCY
An input signal is not received normally.
• Check to see if the input signal matches the
monitor specifications.
• Check the way the signal cable is connected.
• The power indicating lamp is
normally lit but no picture .
• Check the contrast and brightness settings
(adjust them for higher contrast and brightness).
• Check the way the signal cable is connected.
• The display image appears
flowing slantwise.
• Text displayed across the
screen appears vertically
streaked, with the characters
in vertical columns blurred.
• Adjust the dot clock frequency and phase.
(Adjust the dot clock frequency first, the dot clock
phase next.)
(RGB input)
• Text displayed across the
screen appears blurred.
• A fine pattern flickers when
displayed on the screen.
• Adjust the dot clock phase for the clearest
viewing.
(RGB input)
• The remote controller does not work.
• Check to see if the batteries are loaded in the
remote controller in opposite direction.
• Check to see if the batteries in the remote
controller are OK.