Maintenance
The air filter unit of this projector consists of a filter cover, two kinds of filters, and
a filter frame. The new double large filters system is expected to function longer.
However, please check and clean it periodically to keep ventilation needed for
normal operation of the projector.
When the indicators or a message prompts you to clean the air filter, comply with
it as soon as possible. Replace the filters when they are damaged or too soiled.
To prepare new filters, make contact with your dealer and tell the following type
number.
Cleaning and replacing the air filter
Type number : MU06481 (Filter set)
1.
Turn the projector off, and unplug the power cord.
Allow the projector to sufficiently cool down.
2.
Use a vacuum cleaner on and around the filter cover.
3.
While supporting the projector with one hand, use
your other hand to pull the filter cover forward in the
direction of the arrow.
4.
Use a vacuum cleaner for the filter vent of the
projector and the outer side of the filter unit.
5.
Take the filters out while holding the filter cover.
7.
Put the filters back into the filter cover.
Put the coarse meshed filter into a filter cover
first. Then put the fine meshed filter on the coarse
meshed one, turning its stitched side up.
8.
Put the filter unit back into the projector.
When you replace the lamp, please replace the air filter. An air filter of specified
type will come together with a replacement lamp for this projector.
(continued on next page)
Filter cover
Filter unit
Filter cover
Filter (fine meshed)
Filter (coarse meshed)
2
4
3
7
Stitched
side
6.
Use a vacuum cleaner on both sides of the filters.
When vacuuming up the fine meshed filter, hold it
so it will not be sucked in. If the filters are damaged
or heavily soiled, replace them with the new ones.