Hitachi L300P Power Supply User Manual


 
L300P Inverter
Troubleshooting
and Maintenance
6–9
Restoring Factory Default Settings
You can restore all inverter parameters to the original factory (default) settings for the intended
country of use. After initializing the inverter, use the powerup test in Chapter 2 to get the motor
running again. To initialize the inverter, follow the steps below.
NOTE: Initialization cannot be performed with a remote operator panel. Disconnect the device
and use the inverter’s front panel keypad.
No. Action Display Func./Parameter
1
Use the
, , and keys to
navigate to the “B” Group.
“B” Group selected
2
Press the
key.
First “B” parameter selected
3
Press and hold the key until ->
Country code for initializa-
tion selected
4
Press the
key.
00 = Japan, 01 = Europe,
02 = U.S.
5 Confirm the country code is correct. Do not change it unless you are absolutely sure
the power input voltage range and frequency match the country code setting.
To change the country code, press or to set; to store.
6
Press the key.
Country code for initializa-
tion selected
7
Press the key.
Initialization function selected
8
Press the
key.
00 = initialization disabled,
clear trip history only
9
Press the key.
01 = enable initialization
10
Press the key.
Initialization now enabled to
restore all defaults
11
Press and hold the ,
, and
keys. Do not let release yet.
First part of special key
sequence, the “B” is flashing.
12 Holding the keys above, press and
hold the
(STOP) key for 3 sec.
Final part of special key
sequence, “B084” is flashing
13
When the
b
084
display function
begins blinking, release the ,
, , and keys together.
or
Default parameter country
code shown during initializa-
tion process (left-most charac-
ter displays alternating
pattern)
14 Initialization is complete. Function code for output
frequency monitor shown
FUNC.
1
2
b --
FUNC.
b 001
1
b 08
FUNC.
02
1
2
STR
FUNC.
b 085
2
b 084
FUNC.
00
1
01
STR
b 084
FUNC.
1
2
b 084
STOP
RESET
b 084
STOP
RESET
FUNC.
1
2
0 eu
0USA
d 01