L300P Inverter Specifications
Geting Started
1–10
Footnotes for the preceding tables:
Note 1: The protection method conforms to JEM 1030.
Note 2: The applicable motor refers to Hitachi standard 3-phase motor (4-pole). When using
other motors, care must be taken to prevent the rated motor current (50/60 Hz) from
exceeding the rated output current of the inverter.
Note 3: The output voltage decreases as the main supply voltage decreases (except when
using the AVR function). In any case, the output voltage cannot exceed the input
power supply voltage.
Note 4: To operate the motor beyond 50/60 Hz, consult the motor manufacturer for the
maximum allowable rotation speed.
Note 5: The braking resistor is not installed in the inverter. When your application requires a
high regenerative torque, use the optional regenerative braking unit and resistor (see
Chapter 5).
Note 6: The storage temperature refers to the short-term temperature during transport.
Note 7: Conforms to the test method specified in JIS C0911 (1984). For the model types
excluded in the standard specifications, contact your Hitachi sales representative.
Note 8: When using the inverter in a dust-prone area, we recommend the optional varnish
coating specification for the inverter.
Note 9: When using a remote operator keypad and cable, be sure to remove the RJ45 modular
interconnect from the inverter’s keypad port before connecting the cable.
Note 10: When using the inverter from 40° to 50°C ambient, the output current of the inverter
must be derated (see the next section on derating curves).
Note 11: NEMA 1 applies to inverter models up to 30kW (–300xxx). An optional wire-entry
conduit box is required for inverter models 37kW to 75kW (–370 to –750xxx) to
meet the NEMA 1 rating.
Protective functions Over-current, overload, braking resistor overload, over-voltage, EEPROM error, under-
voltage error, CT (current transformer) error, CPU error, external trip, USP error,
ground fault, input over-voltage, instantaneous power failure, inverter thermal trip,
phase failure detection, IGBT error, thermistor error, expansion card 1 error, expansion
card 2 error, under-voltage waiting error
Environ-
ment
Temperature *10 Operating (ambient): -10 to 40°C / Storage: -20 to 65°C
Humidity 20 to 90% humidity (non-condensing)
Vibration *7
Models L300P–110xxx to 300xxx: 5.9 m/s
2
(0.6G), 10 to 55 Hz
Models L300P–370xx to 1320xxx: 2.94 m/s
2
(0.3G), 10 to 55 Hz
Location *8 Altitude 1,000 m or less, indoors (no corrosive gasses or dust)
Coating color Models L300P–110xxx to 750xxx: Blue (D.I C14 version No. 436)
Models L300P–900xx to 1320xxx: Gray (MUNSELL 8.5YR6.2/0.2)
Accessories Digital input PCB SJ-DG (4-digit BCD / 16-bit binary)
Others EMI filters, input/output reactors, DC reactors, radio noise filters, braking resistors,
braking units, LCR filter, communication cables, factory I/O network interface cards
Operator input devices *9 OPE–SRE (4-digit LED with potentiometer) / OPE–S (4-digit LED w/o potentiometer),
Optional: OPE-SR (4-digit LED with potentiometer, Japanese/English overlay),
SRW–0EX Multilingual operator with copy function (English, French, German, Italian,
Spanish, and Portuguese)
Item General Specifications