Maintenance
Air lter (continued)
5.
Apply a vacuum cleaner to the air lter and lter cover.
Then set a new or cleaned air lter into place.
In case of the lter cover for bottom-up use, remove the air lter from the lter
cover and clean each. After cleaning, reattach the cleaned lter to the lter cover.
Please replace the air lter when it is damaged or too soiled.
6.
Position the air lter and lter cover into place.
7.
Slowly turn the projector so that the top is facing up, except for the case of
bottom-up use.
8.
Turn the projector on and reset the lter time using the FILTER TIME function
in the OPTION menu
(
40)
.
(1) Press the MENU button to display a menu. When the EASY MENU has
appeared, please skip the next step (2).
(2) Point at the “OPTION” in the left column of the menu using ▼/▲ button, then
press the ► button.
(3) Point at the “FILTER TIME” using ▼/▲ button, then press the ► button. A
dialog will appear.
(4) Press the ▲ button to select “RESET” on the dialog. It performs resetting the
lter time.
Claws
Air lter
Rail of air lter
Filter cover for bottom-up use
Usual lter cover
Push the points of “PUSH” word
with claws to x the air lter.
Interlocking the tabs,
snap the lter cover into place.
Filter cover for bottom-up use
Interlocking the tabs, snap the lter cover into place.
Tabs