Honeywell MS2421 Barcode Reader User Manual


 
40
Error
Code
Description
28
LASER #2 (RIGHT HORIZONTAL) UNDERCURRENT WARNING – The laser in the right
horizontal scanning subsystem is drawing too little current. The laser is probably not on. This
could be the result of a loss of the required set point in memory. Have the unit checked at an
authorized service center.
29
LASER #3 (LEFT HORIZONTAL) UNDERCURRENT WARNINGThe laser in the left vertical
scanning subsystem is drawing too little current. The laser is probably not on. This could be
the result of a loss of the required set point in memory. Have the unit checked at an
authorized service center.
31
MOTOR #1 (VERTICAL) ERROR The motor in the vertical scanning subsystem denotes a
failure. The scanner will try three times to correct the motor operation. If the motor error
persists, the vertical scanning subsystem will be shut down and this error code will remain on
the Diagnostic Indicators.
32
MOTOR #2 (HORIZONTAL) ERROR The motor in the horizontal scanning subsystem
denotes a failure. The scanner will try three times to correct the motor operation. If the motor
error persists, the horizontal scanning subsystem will be shut down and this error code will
remain on the Diagnostic Indicators.
34
MOTOR #1 (VERTICAL) SPEED ERRORThe motor in the vertical section cannot be speed
controlled as desired. Have the unit checked at an authorized service center.
35
MOTOR #2 (HORIZONTAL) SPEED ERRORThe motor in the horizontal section cannot be
speed controlled as desired. Have the unit checked at an authorized service center.