Honeywell MS9500 Barcode Reader User Manual


 
17
INDICATORS
Audible
When the Voyager is in operation, it provides audible feedback. These sounds
indicate the status of the scanner. Eight settings are available for the tone of the
beep (normal, six alternate tones and no tone). To change the beeper tone, refer
to the MetroSelect
Single-Line Configuration Guide or MetroSet2’s help files.
One Beep
When the scanner first receives power, the green* LED will turn on, the red*
LED will flash, and the scanner will beep once. The scanner is ready to scan.
When the scanner successfully reads a bar code, the red LED will flash and
the scanner will beep once.
Three Beeps
During Operation
When entering the configuration mode, the red* LED will flash while the
scanner simultaneously beeps three times.
When exiting the configuration mode, the scanner will beep three times and
the red LED will stop blinking.
Three beeps can also indicate a communication timeout during normal
scanning mode if the scanner is configured to give this indication.
During Start-up
This is a failure indicator. Refer to “Failure Modes” on page 19.
Three Beeps
When using the single-code-configuration method, the scanner will sound a
3-combination tone (a single beep then a short pause followed by, a high tone,
and a low tone). This beep sequence signals that the single configuration bar
code has successfully configured the scanner.
Razzberry Tone
On startup, this tone indicates a failure mode. Refer to “Failure Modes" on
page 19.
When in configuration mode, a short razzberry tone will sound if an invalid bar
code is scanned.
* In some custom units the standard green LED has been replaced with a blue LED and
the red LED has been replaced with a white LED.