14A-9
SEPTEMBER 2007HUBBELL / CHANCE COMPANY – CENTRALIA, MISSOURI
®
®
POWER SYSTEMS, INC.
Type AR (Automation-Ready) Switch
Catalog Numbering System
Crossarm/Inter-
Phase Shaft
S = Steel
F = Fiberglass
M = Steel crossarm,
berglass
interphase shaft
A
Position 1:
Position 2:
Insulation, kV Impulse
(maximum system kV)
1 = 110 porcelain (17.1kV)
3 = 110 polymer (17.1kV)
4 = 150 polymer (29kV)
6 = 150 polymer
(38kV grounded-wye)
7 = 150 polymer Long Leak (39.6")
(38kV grounded-wye)
R
Configuration
1 = Horizontal
2 = Vertical
3 = Ø-over-Ø
4 = Delta
5 = Inverted
Position 4:
Positions 5 through 12:
See Option Tables for each Conguration
X X X X X
XXX
Option Tables by Configuration
VerticalSwitch,S&FControls
B = Sensor Brackets
* C = Control Insulator
H = Captive Hardware
L = Surge Arrester Brackets
* P = Extra Pipe
* PP = Two Extra Pipes
†
T = Terminal Connectors (ATC 1343)
1
X X
XX
U.S. Patents 6,207,919;
6,215,082; 6,281,460;
6,409,135; 6,459,053;
6,541,717; 6,818,846;
6,946,607.
Position 3:
*Options C, P, R, PP and RR do not apply
when Hook Stick Operated Control is supplied.
†
Options H and T, Captive Hardware and Terminal Con-
nectors, cannot be ordered together.
14.4kV, 25kV or 34.5kV 900 Amperes Continuous/Interrupt
Vertical Switch, T & G Controls
B = Sensor Brackets
* D = Control Insulator
H = Captive Hardware
L = Surge Arrester Brackets
* R = Extra Pipe
* RR = Two Extra Pipes
†
T = Terminal Connectors (ATC 1343)
Replacement Parts
C8180001 Interrupter for all Mounting Congurations
E8181000P Live Parts for all kV Ratiings and Mounting Congurations
Standard Controls — Pipe sizes
on drawings, pages 14A-4 thru -8
(All configurations)
S = All Steel Vertical Sections
F = One Fiberglass Vertical Section
H = Vertical Controls replaced
with Hook stick Operating
Mechanism
Heavy-Duty Controls — 1
1
⁄
4
" IPS
(Vertical and Ø-over-Ø only)
T = All Steel Vertical Sections
G = One Fiberglass Vertical Section
Horizontal and Inverted Switches
B = Sensor Brackets
* C = Control Insulator
†
H = Captive Hardware
L = Surge Arrester Brackets
* P = Extra Pipe
* PP = Two Extra Pipes
S = Steel Crossarm Brace, only one supplied
†
T = Terminal Connectors (ATC 1343)
W = Wood Crossarm Brace, only one supplied
X = Extension Links
Phase-over-PhaseSwitch,S&FControls
B = Sensor Brackets
* C = Control Insulator
†
H = Captive Hardware
L = Surge Arrester Brackets
* P = Extra Pipe
* PP = Two Extra Pipes
†
T = Terminal Connectors (ATC 1343)
X = Extension Links
Phase-over-PhaseSwitch,S&FControls
B = Sensor Brackets
* C = Control Insulator
†
H = Captive Hardware
L = Surge Arrester Brackets
* R = Extra Pipe
* RR = Two Extra Pipes
†
T = Terminal Connectors (ATC 1343)
X = Extension Links
Delta Switch
B = Sensor Brackets
* C = Control Insulator
†
H = Captive Hardware
L = Surge Arrester Brackets
* P = Extra Pipe
* PP = Two Extra Pipes
†
T = Terminal Connectors (ATC 1343)
X = Extension Links