IBM 1476 Laptop User Manual


 
Symptom-to-FRU Index
The Symptom-to-FRU Index lists the symptoms and errors
and the possible causes. The most likely cause is listed
first.
Note: Perform the FRU replacement or actions in the
sequence shown in the FRU/Action columns. If a
FRU does not solve the problem, put the original
part back in the computer. Do not replace a non-
defective FRU.
This index can also be used to help you decide which
FRUs should be available when servicing a computer.
Numeric error codes show the errors detected in POST or
system operation (runtime). In the following error codes, X
can be any number.
If no codes are available, use narrative symptoms.
If the symptom, is not listed, go to “Undetermined
Problems” on page 25.
Note: For any IBM device not supported by the diagnostic
codes in this ThinkPad computer, see the manual
for that device.
Numeric Error Codes and Messages
Error
Code
Message FRU/Action in Sequence
POST
010 Memory Error
at MMMM:
SSSS:
OOOOh
(R:xxxxh,
W:xxxxh)
Go to “Memory Check”
on page 8.
DIMM
Planar board
040 Diskette Drive
Controller
Error
Go to “Diskette Drive
Check” on page 11.
Ensure the diskette
drive configuration
setting in BIOS Utility
is correct.
Diskette drive cable
Diskette drive
Planar board
047 Diskette
Drive(s) Disa-
bled
Ensure the diskette
drive is not set to "Dis-
abled" in the "System
Security" menu of the
BIOS Utility.
Diskette drive cable
Diskette drive
ThinkPad i Series 1400 17