IBM 2292 Computer Hardware User Manual


 
Diagnostic
Error
Code
FRU/Action
014-001-XXX
Parallel
port
Presence
1.
Remove
external
parallel
device,
if
present
2.
Run
setup,
enable
port
3.
System
board
014-002-XXX
014-003-XXX
Parallel
port
Timeout/Parity
error
1.
System
board
014-013-XXX
014-014-XXX
Parallel
port
Control
Signal/Loopback
test
failure
1.
System
board
014-015-XXX
Parallel
port
External
Loopback
failure
1.
Wrap
plug
2.
System
board
014-027-XXX
Parallel
port
Configuration/Setup
error
1.
Run
Setup,
enable
port
2.
Flash
the
system
3.
System
board
014-03X-XXX
014-04X-XXX
Parallel
port
failure
1.
System
board
014-195-XXX
Parallel
port
Test
aborted
by
user
1.
Information
2.
Re-start
the
test,
if
necessary
014-196-XXX
Parallel
port
test
halt,
error
threshold
exceeded
1.
Press
F3
to
review
the
log
file
2.
Re-start
the
test
to
reset
the
log
file
014-197-XXX
Parallel
port
test
warning
1.
Make
sure
the
component
that
is
called
out
is
connected
and/or
enabled
2.
Re-run
test
3.
Component
that
is
called
out
in
warning
statement
4.
Component
under
test
014-198-XXX
Parallel
port
test
aborted
1.
If
a
component
is
called
out,
make
sure
it
is
connected
and/or
enabled
2.
Flash
the
system
and
re-test
3.
Go
to
the
Undetermined
problems
section
014-199-XXX
Parallel
port
test
failed,
cause
unknown
1.
Go
to
the
Undetermined
problems
section
2.
Flash
the
system
and
re-test
3.
Replace
component
under
function
test
014-2XX-XXX
014-3XX-XXX
Parallel
port
failure
1.
External
parallel
device
2.
System
board
015-000-XXX
USB
port
Interface
Test
Passed
1.
No
action
015-001-XXX
USB
port
Presence
1.
Remove
USB
device(s)
and
re-test
2.
System
board
56
Hardware
Maintenance
Manual
Types
2292,
2273,
6043,
6343,
6349,
6350,
6790,
6791,
6792,
6793,
6794,
6795,
6823,
6825