POST
Error
Code
FRU/Action
1117
Failed
baud
rate
test
1.
Run
Enhanced
Diagnostics
1162
Serial
port
configuration
error
1.
Run
Configuration
2.
Serial
Adapter
(if
installed)
3.
System
Board
11XX
Not
listed
above
1.
System
Board
1201
1.
System
Board
2.
Any
Serial
Device
1202,
1206,
1208,
1209,
12XX
1.
Dual
Async
Adapter/A
2.
System
Board
3.
Any
Serial
Device
1207
1.
Communications
Cable
2.
Dual
Async
Adapter/A
13XX
1.
Game
Adapter
1402
Printer
not
ready
Information
only
1403
No
paper
error,
or
interrupt
failure
Information
only
1404
System
board
timeout
failure
1.
Run
Enhanced
Diagnostics
1405
Parallel
adapter
error
1.
Run
Enhanced
Diagnostics
1406
Presence
test
error
1.
Run
Enhanced
Diagnostics
14XX
Not
listed
above.
Check
printer
before
replacing
system
board
1.
Printer
2.
System
Board
15XX
1.
SDLC
Adapter
1692
Boot
sequence
error
1.
Run
FDISK
to
ensure
at
least
one
active
partition
is
set
active
16XX
1.
36/38
Workstation
Adapter
1762
Hard
disk
drive
configuration
error
1.
Run
Configuration.
(See
“Setup
Utility
program”
on
page
14.)
1780
(Disk
Drive
0)
1781
(Disk
Drive
1)
1782
(Disk
Drive
2)
1783
(Disk
Drive
3)
1.
Hard
Disk
Drive
2.
System
Board
3.
Riser
card
4.
Hard
Disk
Cable
5.
Power
Supply
Chapter
7.
Symptom-to-FRU
index
75