IBM 6579 Personal Computer User Manual


 
POST Error Code FRU/Action
10153
1. Data/Fax Modem
2. System Board
101XXNot listed above
1. Modem Adapter/A
2. Data/Fax Modem
3. System Board
10450, 10451, 10490,
10491, 10492, 10499Read/write error
1. Run Enhanced Diagnostics
2. Hard Disk Drive
3. System Board
10452Seek test error
1. Run Enhanced Diagnostics
10453Wrong drive type? Information only
10454Sector buffer test error
1. Run Enhanced Diagnostics
10455, 10456Controller error
1. Run Enhanced Diagnostics
10459Drive diagnostic command error Information only
10461Drive format error
1. Run Enhanced Diagnostics
10462Controller seek error
1. Run Enhanced Diagnostics
10464Hard Drive read error
1. Run Enhanced Diagnostics
10467Drive non-fatal seek error
1. Run Enhanced Diagnostics
10468Drive fatal seek error
1. Run Enhanced Diagnostics
10469Drive soft error count exceeded
1. Run Enhanced Diagnostics
10470, 10471, 10472Controller wrap error
1. Run Enhanced Diagnostics
10473Corrupt data. Low level format might be
required
Information only
10480
1. Hard Disk Drive (ESDI)
2. Drive Cable
3. System Board
10481ESDI drive D seek error
1. Run Enhanced Diagnostics
10482Drive select acknowledgement bad
1. Run Enhanced Diagnostics
106X1
1. Check Configuration
2. Ethernet Adapter
162 Hardware Maintenance Manual: IBM NetVista Computer Types 6058, 6059, 6269, 6568, 6569, 6578, 6579, 6648,
6649