IBM 8186 Computer Hardware User Manual


 
Diagnostic Error Code FRU/Action
001-026-XXX
System FLASH data error
1. Flash the system
2. System board
001-027-XXX
System Configuration/Setup error
1. Run Setup
2. Flash the system
3. System board
001-032-XXX
System Device Controller failure
System board
001-034-XXX
System Device Buffer Allocation failure
1. Reboot the system
2. Flash the system
3. Run memory test
4. System board
001-035-XXX
System Device Reset condition detected
System board
001-036-XXX
System Register error
System board
001-038-XXX
System Extension failure
1. Adapter card
2. System board
001-039-XXX
System DMI data structure error
1. Flash the system
2. System board
001-040-XXX
System IRQ failure
1. Power-off/on system and re-test
2. System board
001-041-XXX
System DMA failure
1. Power-off/on system and re-test
2. System board
001-195-XXX
System Test aborted by user
1. Information
2. Re-start the test, if necessary
001-196-XXX
System test halt, error threshold exceeded
1. Press F3 to review the log file
2. Re-start the test to reset the log file
001-197-XXX
System test warning
1. Make sure the component that is called
out is connected and/or enabled
2. Re-run test
3. Component that is called out in warning
statement
4. Component under test
001-198-XXX
System test aborted
1. If a component is called out, make sure
it is connected and/or enabled
2. Flash the system and re-test
3. Go to “Undetermined problems” on page
109
001-199-XXX
System test failed, cause unknown
1. Go to “Undetermined problems” on page
109
2. Flash the system and re-test
3. Replace component under function test
001-250-XXX
System ECC error
1. System board
72 Hardware Maintenance Manual