IBM 8194 Computer Hardware User Manual


 
POST Error Code FRU/Action
1117
Failed baud rate test
Run Enhanced Diagnostics
1162
Serial port configuration error
1. Run Setup.
2. Serial Adapter
(if installed)
3. System Board
11XX
Not listed above
System Board
1201
1. System Board
2. Any Serial Device
1202, 1206, 1208, 1209, 12XX
1. Dual Async Adapter/A
2. System Board
3. Any Serial Device
1207
1. Communications Cable
2. Dual Async Adapter/A
13XX Game Adapter
1402
Printer not ready
Information only
1403
No paper error, or interrupt failure
Information only
1404
System board timeout failure
Run Enhanced Diagnostics
1405
Parallel adapter error
Run Enhanced Diagnostics
1406
Presence test error
Run Enhanced Diagnostics
14XX
Not listed above. Check printer before
replacing system board
1. Printer
2. System Board
15XX SDLC Adapter
1692
Boot sequence error
Run FDISK to ensure at least one active
partition is set active
16XX 36/38 Workstation Adapter
1762
Hard disk drive configuration error
Run Setup. (See Chapter 5, “IBM Setup
Utility program,” on page 19.)
1780 (Disk Drive 0)
1781 (Disk Drive 1)
1782 (Disk Drive 2)
1783 (Disk Drive 3)
1. Hard Disk Drive
2. System Board
3. Riser card
4. Hard Disk Cable
5. Power Supply
1800 PCI/PnP Error! No Hardware Interrupt
Available
1. Run Setup and verify PCI/ISA
configuration settings.
2. Rerun diagnostics.
3. PCI Adapter
Chapter 7. Symptom-to-FRU Index 97