IBM 8197 Computer Hardware User Manual


 
POST Error Code FRU/Action
167
No Processor BIOS Update Found
1. Run Setup. Check Stepping level for
the BIOS level needed, then perform
the flash update.
2. Processor
168
Alert on LAN error
1. Run Setup. Check to see that Ethernet
and Alert on LAN are enabled.
2. System Board
17X, 18X C2 Security
175 Primary Copy of Secure Data is
damaged
1. Run Setup. See Chapter 5, “IBM Setup
Utility program,” on page 19.
2. System Board
176 The System has been tampered with
1. Covers were removed from the
computer
177
Corrupted Administrator Password
System Board
178 System Board
179 Boot Integrity Services Segment Error System Board
183
1. Enter the administrator password
184
Asset Control Antenna not detected
1. Make sure Asset Care and Asset ID are
enabled in the IBM Setup Utility
program.
2. RFID Antenna
3. System Board
185
Corrupted boot sequence
Set configuration and reinstall the boot
sequence
186 Security Hardware Control Logic Error System Board
187
1. Clear Administration password
2. System Board
189 More than three password attempts were
made to access the computer
190
System Security: Invalid Remote Change
Requested
System Board
191 System Security: IBM Embedded
Security Hardware Reset
System Board
193 System Security: IBM Embedded
Security Hardware Removed
System Board
194 System Security: Asset ID Antenna has
been Removed
System Board
195 System Security: Asset ID Antenna has
been Installed
System Board
196 System Tampered Cleared System Board
1XX
Not listed above
System Board
94 Hardware Maintenance Manual