IBM 8197 Computer Hardware User Manual


 
Diagnostic Error Code FRU/Action
015-197-XXX
USB port test warning
1. Make sure the component that is called
out is connected and/or enabled
2. Re-run test
3. Component that is called out in warning
statement
4. Component under test
015-198-XXX
USB port test aborted
1. If a component is called out, make sure
it is connected and/or enabled
2. Flash the system and re-test
3. Go to “Undetermined problems” on page
109
015-199-XXX
USB port test failed, cause unknown
1. Go to “Undetermined problems” on page
109
2. Flash the system and re-test
3. Replace component under function test
018-000-XXX
PCI Card Test Passed
No action
018-0XX-XXX
PCI Card Failure
1. Riser card, if installed
2. System board
018-195-XXX
PCI Card Test aborted by user
1. PCI card
2. Information
3. Re-start the test, if necessary
018-196-XXX
PCI Card test halt, error threshold exceeded
1. Press F3 to review the log file
2. Re-start the test to reset the log file
018-197-XXX
PCI Card test warning
1. Make sure the component that is called
out is connected and/or enabled
2. Re-run test
3. Component that is called out in warning
statement
4. Component under test
018-198-XXX
PCI Card test aborted
1. Make sure the component that is called
out is connected and/or enabled
2. Flash the system and re-test
3. Go to “Undetermined problems” on page
109
018-199-XXX
PCI Card test failed, cause unknown
1. Go to “Undetermined problems” on page
109
2. Flash the system and re-test
3. Replace component under function test
018-250-XXX
PCI Card Services error
1. PCI card
2. Riser card, if installed
3. System board
020-000-XXX
PCI Interface Test Passed
No action
Chapter 7. Symptom-to-FRU Index 79