IBM 8312 Computer Hardware User Manual


 
Diagnostic
Error
Code
FRU/Action
000-197-XXX
BIOS
test
warning
1.
Make
sure
the
component
that
is
called
out
is
connected
and/or
enabled
2.
Re-run
test
3.
Component
that
is
called
out
in
warning
statement
4.
Component
under
test
000-198-XXX
BIOS
test
aborted
1.
If
a
component
is
called
out,
make
sure
it
is
connected
and/or
enabled
2.
Flash
the
system
and
re-test
3.
Go
to
the
Undetermined
problems
section
000-199-XXX
BIOS
test
failed,
cause
unknown
1.
Go
to
the
Undetermined
problems
section
2.
Flash
the
system
and
re-test
3.
Replace
component
under
function
test
000-250-XXX
BIOS
APM
failure
1.
Flash
the
system
2.
System
board
000-270-XXX
BIOS
ACPI
failure
1.
Flash
the
system
2.
System
board
001-000-XXX
System
Test
Passed
1.
No
action
001-00X-XXX
System
Error
1.
System
board
001-01X-XXX
System
Error
1.
System
board
001-024-XXX
System
Addressing
test
failure
1.
System
board
001-025-XXX
System
Checksum
Value
error
1.
Flash
the
system
2.
System
board
001-026-XXX
System
FLASH
data
error
1.
Flash
the
system
2.
System
board
001-027-XXX
System
Configuration/Setup
error
1.
Run
Setup
2.
Flash
the
system
3.
System
board
001-032-XXX
System
Device
Controller
failure
1.
System
board
001-034-XXX
System
Device
Buffer
Allocation
failure
1.
Reboot
the
system
2.
Flash
the
system
3.
Run
memory
test
4.
System
board
001-035-XXX
System
Device
Reset
condition
detected
1.
System
board
001-036-XXX
System
Register
error
1.
System
board
90
Hardware
Maintenance
Manual