Refer to the following diagnostic error codes when using the diagnostic tests. See
“Running diagnostics tests” on page 13 for the specific type for information about
the Diagnostic programs.
In the following index, X can represent any number.
Diagnostic Error Code FRU/Action
000-000-XXX
BIOS Test Passed
1. No action
000-002-XXX
BIOS Timeout
1. Flash the system. See “Flash update
procedures” on page 148
2. System board
000-024-XXX
BIOS Addressing test failure
1. Flash the system. See “Flash update
procedures” on page 148
2. System board
000-025-XXX
BIOS Checksum Value error
1. Flash the system. See “Flash update
procedures” on page 148
2. Boot block
3. System board
000-026-XXX
FLASH data error
1. Flash the system. See “Flash update
procedures” on page 148
2. Boot block
3. System board
000-027-XXX
BIOS Configuration/Setup error
1. Run Setup
2. Flash the system. See “Flash update
procedures” on page 148
3. Boot block
4. System board
000-034-XXX
BIOS Buffer Allocation failure
1. Reboot the system
2. Flash the system. See “Flash update
procedures” on page 148
3. Run memory test
4. System board
000-035-XXX
BIOS Reset Condition detected
1. Flash the system. See “Flash update
procedures” on page 148
2. System board
000-036-XXX
BIOS Register error
1. Flash the system. See “Flash update
procedures” on page 148
2. Boot block
3. System board
000-038-XXX
BIOS Extension failure
1. Flash the system. See “Flash update
procedures” on page 148
2. Adapter card
3. System board
Chapter 7. Symptom-to-FRU Index 49