IBM 8418 Personal Computer User Manual


 
Diagnostic Error Code FRU/Action
030-197-XXX
SCSI interface test warning
1. Make sure the component that is called
out is connected and/or enabled. See
Chapter 5, “Using the IBM Setup
Utility,” on page 19
2. Re-run test
3. Replace the component that is called out
in warning statement
4. Replace the component under test
030-198-XXX
SCSI interface test aborted
1. If a component is called out, make sure
it is connected and/or enabled. See
Chapter 5, “Using the IBM Setup
Utility,” on page 19
2. Flash the system and re-test. See “Flash
update procedures” on page 148
3. Go to “Undetermined problems” on page
89
030-199-XXX
SCSI interface test failed, cause unknown
1. Go to “Undetermined problems” on page
89
2. Flash the system and re-test. See “Flash
update procedures” on page 148
3. Replace component under function test
035-000-XXX
RAID interface Test Passed
1. No action
035-0XX-XXX
RAID interface Failure
1. RAID signal cable
2. RAID device
3. RAID adapter card, if installed
4. System board
035-195-XXX
RAID interface Test aborted by user
1. Information
2. Re-start the test, if necessary
035-196-XXX
RAID interface test halt, error threshold
exceeded
1. Press F3 to review the log file
2. Re-start the test to reset the log file
035-197-XXX
RAID interface test warning
1. Make sure the component that is called
out is connected and/or enabled. See
Chapter 5, “Using the IBM Setup
Utility,” on page 19
2. Re-run test
3. Replace the component that is called out
in warning statement
4. Replace the component under test
035-198-XXX
RAID interface test aborted
1. If a component is called out, make sure
it is connected and/or enabled. See
Chapter 5, “Using the IBM Setup
Utility,” on page 19
2. Flash the system and re-test. See “Flash
update procedures” on page 148
3. Go to “Undetermined problems” on page
89
62 Hardware Maintenance Manual