IBM 8419 Personal Computer User Manual


 
POST Error Code FRU/Action
1207
1. Communications Cable
2. Dual Async Adapter/A
13XX
1. Game Adapter
1402
Printer not ready
Information only
1403
No paper error, or interrupt failure
Information only
1404
System board timeout failure
1. Run Enhanced Diagnostics
1405
Parallel adapter error
1. Run Enhanced Diagnostics
1406
Presence test error
1. Run Enhanced Diagnostics
14XX
Not listed above. Check printer before
replacing system board
1. Printer
2. System Board
15XX
1. SDLC Adapter
1692
Boot sequence error
1. Run FDISK to ensure at least one active
partition is set active
16XX
1. 36/38 Workstation Adapter
1762
Hard disk drive configuration error
1. Run Setup. (See “Starting the IBM
Setup Utility program” on page 19.).
1780 (Disk Drive 0)
1781 (Disk Drive 1)
1782 (Disk Drive 2)
1783 (Disk Drive 3)
1. Hard Disk Drive
2. System Board
3. Riser card
4. Hard Disk Cable
5. Power Supply
1800 PCI/PnP Error! No Hardware Interrupt
Available
1. Run Setup and verify PCI/ISA
configuration settings.
2. Rerun diagnostics.
3. PCI Adapter
1801 PCI/PnP Error! No Space Available to
Shadow ROM
1. Run Setup and verify PCI/ISA
configuration settings.
2. Rerun diagnostics.
3. PCI Adapter
1802 PCI/PnP Error! Not Enough I/O Space
Available
1. Run Setup and verify PCI/ISA
configuration settings.
2. Rerun diagnostics.
3. PCI Adapter
1803 PCI/PnP Error! Not Enough Memory
Space Available
1. Run Setup and verify PCI/ISA
configuration settings.
2. Rerun diagnostics.
3. PCI Adapter
78 Hardware Maintenance Manual