IBM 8490 Server User Manual


 
Table 2. Abbreviated list of POST error codes (continued)
v Follow the suggested actions in the order in which they are listed in the Action
column until the problem is solved.
v See the parts listing in the Problem Determination and Service Guide to determine
which components are customer replaceable units (CRU) and which components
are field replaceable units (FRU).
v If an action step is preceded by “(Trained service technician only),” that step must
be performed only by a trained service technician.
Error code Description Action
1810 PCI error.
1. Make sure that no devices
have been disabled in the
Configuration/Setup Utility
program.
2. Remove the adapters from the
PCI, PCI-X, or PCI Express
slots.
3. Reseat the following
components:
a. Failing adapter
Note: If an error LED is lit
on an adapter, reseat that
adapter first; if no LEDs are
lit, reseat each adapter one
at a time, restarting the
server each time, to isolate
the failing adapter.
b. PCI-X expansion card (if
failing adapter is on the
card)
4.
Replace the following
components one at a time, in
the order shown, restarting the
server each time:
a. Failing adapter
b. PCI-X expansion card (if
failing adapter is on the
card)
c. (Trained service technician
only) System board
58 xSeries 206m Types 8485 and 8490: Installation Guide