IBM MT 9443 Laptop User Manual


 
Symptom-to-FRU index
The symptom-to-FRU index in this section lists symptoms and errors and their
possible causes. The most likely cause is listed first, in boldface type.
Note: Do the FRU replacement or other actions in the sequence shown in the
column headed “FRU or action, in sequence.” If replacing a FRU does not
solve the problem, put the original part back in the computer. Do not
replace a nondefective FRU.
This index can also help you determine, during regular servicing, what FRUs are
likely to need to be replaced next.
A numeric error is displayed for each error detected in POST or system operation.
In the displays, n can be any number.
If no numeric code is displayed, check the narrative descriptions of symptoms. If
the symptom is not described there, go to “Intermittent problems” on page 51.
Note
For a device not supported by diagnostic codes in the ThinkPad notebook
computers, see the manual for that device.
Numeric error codes
Symptom or error FRU or action, in sequence
0175
Bad CRC1, stop POST task—The EEPROM
checksum is not correct.
System board.
0176
System Security—The system has been
tampered with.
1. Run BIOS Setup Utility, and save the
current setting by pressing F10.
2. System board.
0177
Bad
SVP data, stop POST task—The
checksum of the supervisor password in the
EEPROM is not correct.
System board.
0182
Bad CRC2. Enter BIOS Setup and load Setup
defaults.—The checksum of the CRS2 setting
in the EEPROM is not correct.
1. Run BIOS Setup Utility. Press F9, and
Enter to load the default setting. Then
save the current setting by pressing F10.
2. System board.
0185
Bad startup sequence settings. Enter BIOS
Setup and load Setup defaults.
1. Run BIOS Setup Utility. Press F9, and
Enter to load the default setting. Then
save the current setting by pressing F10.
0187
EAIA data access error—The access to
EEPROM is failed.
System board.
0188
Invalid RFID Serialization Information Area.
System board.
0189
Invalid RFID configuration information
area—The EEPROM checksum is not correct.
System board.
Symptom-to-FRU index
44 MT 8747, 8749, 9440, 9441, 9442, 9443, and 9448