IBM Netcool/OMNIbus Probe for Nortel CNM Network Router User Manual


 
Probe for Nortel CNM 7
Command line interface
The Probe for Nortel CNM is supplied with a command line interface (CLI). This interface
allows you to perform commands using the probe (for example, to acknowledge alarms or
to request a full resynchronization of the CORBA interface).
To use the CLI, you must use the CommandPort property in the properties file to specify a
port through which commands will be sent. When you want to perform commands, telnet
to this port. Table 4 describes the commands that you can use with the command line
interface.
NV_STATE_CHANGE_DEFINITION t
NV_MONITORED_ATTRIBUTES u
NV_PROPOSED_REPAIR_ACTIONS v
NV_CORRELATED_NOTIFICATIONS w
NV_REASON x
CLEAR_USER_ID y
CLEAR_SYSTEM_ID z
NV_ALARM_LIST_ALIGNMENT_
REQUIREMENT
ff
NV_SERVICE_USER gg
NV_SERVICE_PROVIDER hh
NV_SECURITY_ALARM_DETECTOR ii
NV_VENDOR_SPECIFIC_ALARM_TYPE jj
NV_ALARM_RAISED_TIME kk
NV_ALARM_CLEARED_TIME ll
Table 3. Token mappings (2 of 2)
Element Token
Table 4. CLI commands (1 of 2)
Command Description
acknowledge_alarm Allows you to acknowledge an alarm in the 3GPP2
interface.
Note: This command takes as a parameter the
NV_ALARM_ID of the alarm being
acknowledged. Only one alarm can be
acknowledged at a time.
help Displays online help about the CLI.
resynch_all Allows you to perform a full resynchonization with
the 3GPP2 interface.