ICP DAS USA MSM-508FC Switch User Manual


 
Industrial Redundant Ring Switch – Managed Switch Console Manual
Release No. : 0804-V1 14
Parameters
Parameter Description
time Provides the time interval(ms) that you want to set up as the maximum time
Example
Return message: “max age time X (Y) ms. ”
“X” ( switch value) indicates the mtime value set by console command,
“Y” (operating value) indicates the actual operating value.
Value can be specified only on STP Mode (refer to HMIVLAUE setting).
HTIME [time]
Description
This command enables you to set the spanning tree bridge hello time in millisecond (ms).
Hello time is the interval between transmissions of spanning tree configuration messages.
All bridges send configuration messages during reconfiguration to select the designated
root bridge (in this case, the switch port).
Parameters
Parameter
Description
time Provides the time interval(ms) that you want to set up as the hello time
Example
Return message: “hello time X (Y) ms. ”
“X” (switch value) indicates the htime value set by console command,
“Y” (operating value) indicates the actual operating value.
Value can be specified only on STP Mode (refer to HMIVLAUE setting).