Track Selection
There are three tracks on a magnetic stripe card that can contain
encoded data. This option selects the tracks that will be decoded. Note
that the magnetic stripe reader must have heads aligned for reading the
specified tracks.
H1<ENTER>A for Track 2 Only
H1<ENTER>B for Track 1 Only
H1<ENTER>C for Track 3 Only
H1<ENTER>D for Tracks 1 & 2
H1<ENTER>E for Tracks 2 & 3
H1<ENTER>F for Any Track
H1<ENTER>G for All Tracks
Send Start/Stop Sentinel
The tracks of a magnetically-encoded card contain special Start/Stop
Sentinel characters. If this option is enabled, the Start/Stop Sentinel
characters will be transmitted as part of the data stream. If this option is
not selected, the Sentinel characters are suppressed before transmis-
sion.
H2<ENTER>A for Send Start/Stop Sentinels
H2<ENTER>B for Do Not Send Start/Stop Sentinels
Send Accout Number Only
Track Two of a magnetically encoded credit card contains the account
number information. If this option is selected, all other data contained
on the track is suppressed before transmission.
H3<ENTER>A for Send Account Number Only
H3<ENTER>B for Send All Track 2 Information
Track Separator
One character from the Full ASCII Table: This option allows the user to
select the character used to separate data decoded from each track
when using multiple track magnetic stripe readers.
H4<ENTER><SELECTED CHARACTER>
Note: For no track separator, enter N.
Code ID Definition
If the Code ID option is enabled in General Setup, the user can select
the character used to identify each symbology. These characters may
be read from the ASCII Table in Appendix A.
1. Enter CODE ID DEFINITION SETTINGS MODE by typing /E/D/FI.
2. Press <ENTER>.
3. Type the one or two-character code for the selection you wish to
make.
4. Enter the characters in the left column to select the symbology.
5. Enter one character from Appendix A for the new ID.
a UPC-A Default = a
b UPC-E Default = b
c EAN-8 Default = c
d EAN-13 Default = d
e Code 39 Default = e
f Interleaved 2 of 5 Default = f
g Industrial 2 of 5 Default = g
h Code 128 Default = h
i MSI/Plessey Default = i
j Codabar Default = j
k MSR Track 1 Default = k
l MSR Track 2 Default = l
m MSR Track 3 Default = m
6. Save your selection by pressing <ENTER>.
7. Exit the group setup mode by entering IZ<ENTER>.
8. To review the current setting, enter IY<ENTER>.
9. To reset the terminal type setting to default, enter IX<ENTER>.