IMC Networks Giga-AcessEtherLinx-II Switch User Manual


 
31
Strongly recommended:
128 MB RAM
Pentium III 650Mhz or Faster
17” Monitor @ 1024 x 768 Resolution or higher
Installing and Using iView²
iView² is available to install as a download at
www.imcnetworks.com/Products/iView.cfm.
When using iView² with HP OpenView
During the installation, the iView² application will ask if HP Open View is installed on
the management PC. Click
Yes
to integrate the appropriate files. Once in
OpenView, select IMC Networks from the toolbar to view the IMC Networks devices.
When Not Using iView
²
When using an application other than iView² for management, integrate the SNMP
vendor files (a.k.a. MIBs) into the application. The SNMP agent uses the following
Enterprise-specific MIB file and standard MIBs, which can be found in the MIB
directory within the iView
²
download files.
Using the IMC MIBs
Refer to the MIBs folder located with the iView² software for product-related MIBs.
DC Power Supply Wiring Instructions
DC Power Supply
If in a -48 environment:
Chassis
Gnd
Terminal Block
DC Power Supply
If in a +48 environment:
Chassis
Gnd
Terminal Block
NOTE
Incorrect wiring will result in chassis malfunction. The Giga-AccessEtherLinX-II (DC) is
compliant with Isolated Grounding Plane practices. The POSITIVE and NEGATIVE terminals
are isolated from chassis ground and must have a ground reference at the power-sourcing
equipment.
GND
(Common)
GND
(Common)
-48
+48