26
Cable length, wire gauge and power conditioning devices play a major role
in the performance of your IMS Driver and Motor.
NOTE: The length of the DC power supply cable between the IMS Driver
and the Motor should not exceed 50 feet.
Example A demonstrates the recommended cable configuration for the IMS
Driver to Motor cabling under 50 Feet long. If cabling of 50 feet or longer is
required, the additional length can be gained with the cable configuration in
Example B.
Correct AWG wire size is determined by the current requirement plus cable
length. Please see the IMS Driver to Motor Cable AWG Table in this Appendix.
Shield to Earth Ground
on Supply End Only
Two Shielded/Twisted Pairs
(Wire Size from
IMS Driver to Motor Cable AWG Table)
Ferrite
Beads
Cable Length
less than 50 Feet
Phase A
Phase A
Phase B
Phase B
Phase A
Phase A
Phase B
Phase B
Example A - Cabling Under 50 Feet,
IMS Driver to Motor
Recommended Cable Configurations:
IMS Driver to Motor