InFocus C315. Projector User Manual


 
34
Be extremely careful when removing the lamp housing. In the unlikely
event that the lamp ruptures, small glass fragments may be generated.
The lamp module is designed to contain most of these fragments, but
use caution when removing it. Before replacing a ruptured lamp, clean
the lamp compartment and dispose of cleaning materials. Wash hands
after lamp replacement.
Hg – Lamp contains mercury. Manage in accordance with local
disposal laws. See www.lamprecycle.org.
5 Detach the lamp connector from the projector by gently pulling the con-
nector until it is disconnected from the projector.
6 Carefully remove the lamp module by grasping and lifting the metal
bail wire. Dispose of the lamp in an environmentally proper manner.
7 Install the new lamp module, making sure that it is properly seated. Be
careful not to touch the interior components of the projector.
8 Snap the bail wire back into its flat position against the lamp module.
9 Re-attach the lamp connector to the projector. Make sure the connector is
fully inserted.
10 Tighten the screw on the lamp module.
11 Replace the lamp door.
12 Plug in the power cable then press the Power button to turn the projec-
tor back on, then reset the lamp hour timer.
Resetting the lamp timer
To reset the lamp timer, navigate to the Settings>Service menu and select
Reset Lamp Hours.
disconnect lamp connector
remove module using bail wire
reset lamp time in Service menu