InFocus IN5124 Projector User Manual


 
RS-232 Communication / Network command table (continued)
30
(continued on next page)
Function Command RW Min Max Default Step
Freeze
0: Off
1: On
FRZ RW 0 1 0
INFOCUS UNIQUE
About (Source Info)
0: n/a
1: enable
ABT W 0 1 n/a
Lamp Lit
0: not lit
1: lit
LML R 0 1 0
Number of Lamp Resets LMR R 0 32766 0
Lamp Total On Time (All Bulbs) LMT R 0 2147483646 0
Time In Hours Last
Bulb1 Lasted
LB1 R 0 32766 0
Time In Hours Last
Bulb2 Lasted
LB2 R 0 32766 0
Time In Hours Last
Bulb3 Lasted
LB3 R 0 32766 0
Lamp Hours LMP R 0 32766 0
Filter Hours FLT R 0 32766 0
Unit Total Time On ONL R 0 2147483646 0
Error Status
0: No Error
1: Lamp won't strike
2: reserved
3: Lamp unexpectedly goes out
4: Fan failure
5: Over Temp Condition
6: reserved
7: Lamp Cover Error
8: Overheating alarm
9: Lamp Time Over
10: Temp Sensor out
11: Filter Time Over
12: Unidentiable Error (system
failure)
ERR R 0 12 0