IN8606HD User’s Manual
–52 –
APPENDIX I
Serial Communication
The following table describes the serial communication configuration that should be used when
interfacing to CLI via the serial port.
Windows HyperTerminal or ProComm are two tools that can be used to send CLI commands across
the serial port.
Setting Value
Bits per second 19200
Data bits 8
Parity None
Stop bits 1
Flow control None
Emulation VT100
No Function Command RW Min Max Default Step Parameter
1V
AC Power On
(Auto power on)
APO RW 0 1 0 1
0:Disable; 1:Enable
3V Aspect Ratio ARZ RW 0 5 0 1
0:Fill
1:4:3
2:16:9
3:Letterbox
4:Native
5:2.35:1
4V Auto Image AIM W n/a 1 1 1 1:Enable
5V Auto Off Time AOT RW 0 36 6 1
0:Never
1~36 * 5 = ? min
1:5min
6:30min (Default)
36:180min
6V Auto Source ASC RW 0 1 1 1 0:Disable; 1:Enable
7V Blank Screen BLK RW 0 1 0 1 0:Disable; 1:Enable
9V Brightness BRT RW 0 100 50 1
Valid only when Display
Mode = User
11V
Projection
(Ceiling mode)
CEL RW 0 3 0 1
0:Front
1:Rear
2:Ceiling
3:Ceiling+Rear
12V
Closed Captions: Non-
Muted
CLC RW 0 1 0 1
Off
On (CC1)
14V Color CLR RW 0 100 50 1
Video S-Video only = satu-
ration
15
(None)
Color Space CSM RW 0 2 0 1
Valid only when Display
Mode = User
0:Auto
1:RGB
2:YUV