Warning
Read all caution and safety
statements in this document
before performing any of the
instructions. Also see the Intel
®
Server Board and Server Chassis
Safety Information document at:
http://www.intel.com/support/
motherboards/server/sb/cs-010770
.htm for complete safety information.
Warning
Installation and service
of this product to be
performed only by
qualified service personnel
to avoid risk of injury from
electrical shock or energy
hazard.
Caution
Observe normal ESD
[Electrostatic Discharge]
procedures during system
integration to avoid possible
damage to server board and/or
other components.
Tools Required
Anti-static
wrist strap
Phillips*
screwdriver
Flat Blade
screwdriver
Intel is a registered trademark of Intel Corporation or its subsidiaries in the United States and other countries. *Other names and brands may be claimed as the
property of others. Copyright © 2012, Intel Corporation. All rights reserved.
Intel
®
Server System P4000IP Family Product Configuration
= Configuration Feature
Thermal Operation and Configuration Requirements
To keep the system operating within supported maximum thermal limits, the system must meet the following operating and configuration guidelines:
• Ambient in-let temperature cannot exceed 35º C and should not remain at this maximum level for long periods of time. Doing so may affect
long term reliability of the system.
• The CPU-1 processor and CPU heatsink must be installed.
DIMM Population on CPU-1: Install DIMMs in order; Channels A, B, C, and D. Start with 1st DIMM slot (blue) on each channel.
DIMM Population on CPU-2: Install DIMMs in order; Channels E, F, G, and H. Start with 1st DIMM slot (blue) on each channel.
• All hard drive bays must be populated. Hard drive carriers either can be populated with a hard drive or supplied drive blank.
• The air duct must be installed at all times.
• In single power supply configurations, the second power supply bay must have the supplied filler blank installed at all times.
• The system top-cover must be installed at all times.
8 x 3.5" Hot Swap
8 x 2.5" Hot Swap
16 x 2.5" Hot Swap
24 x 2.5" Hot Swap
N/A
Hard DrivesSystem Fan Power Supply
Intel® Server
System
Five
Hot Swap
System
Fans
(80 x 38 mm)
P4308IP4LHGC
P4308IP4LHJC
P4308IP4LHJCL
P4308IP4LHKC
P4208IP4LHGC
P4216IP4LHJC
P4216IP4LHKC
P4224IP4LHKC
Two Hot Swap
CRPS 750W
Two Hot Swap
CRPS 1200W
Two Hot Swap
CRPS 1600W
4 x 3.5 Fixed
Hard Drives
System Fan Power Supply
Intel®
Workstation
System
Two Fixed System Fans
(120x38mm)
P4304CR2LFGN
One Hot Swap
CRPS 750W
P4304CR2LFKN
P4304CR2LFJN
P4304CR2LFJNL
One Hot Swap
CRPS 1600W
One Hot Swap
CRPS 1200W
Intel
®
Workstation System P4000CR Family Product Configuration