Kathrein UFX 314 Network Card User Manual


 
4
2. Mechanical layout
The points are described in the plan view from left to right.
2.1 Rear view
Redundant Power System Expansion connection for monitoring a redundant power supply, currently has
no function
Modem USB port for connecting a modem (see section 6) or a USB stick
Power Power connection 12.5 V/approx. 200 mA (without controller or USB device),
max. 900 mA
12 x Mini-DIN sockets For the connection of up to 12 UFO
®
compact channel units
2.2 Front view
12 x port LEDs These LEDs are used to indicate the channel unit to which a control unit is
currently connected
3 status LEDs Error (red), Event (yellow), Power (green)
Reset button For manually re-starting the device
Mini-DIN socket For the connection of a handheld controller
USB device port For the connection to a PC, with USW 30
RJ45 socket 10/100 Mbit Ethernet, for connecting several UFX 314 and a control PC
2.3 status LEDs
The Power LED illuminates as soon as the UFX 314 is supplied with power. The status is indicated using the Error
LED and Event LED. The Event LED illuminates during the start phase and extinguishes as soon as the UFX 314
is ready. The Error LED and Event LED illuminate continuously during a software update. At the end of the update,
the Event LED extinguishes. When the device is then re-started, the Error LED also extinguishes, and the Event
LED illuminates at the start.
In normal operation, the Error LED and Event LED signal the presence of messages. An illuminated Event LED
signi es that information has been written to the log. If the Event LED is ashing, a warning has been generated,
it should still be possible to continue to operate the UFX 314. The ashing Error LED signi es that an error
has occurred and the correct operation of the UFX 314 is no longer assured. If the Error and Event LED ash
alternately, a serious error has occurred making normal operation more or less impossible.