Kodak 5600 Projector User Manual


 
SERVICE MANUAL
8 18NOV97 – SM5440-1
Replacing the WORM PULLEY and MECHANISM BELT
Warning
Dangerous Voltage
[1] Disconnect the main power.
[2] Do the replacement procedure for the LOWER HOUSING ASSEMBLY.
[3] Do the replacement procedure for the MOTOR except do not disconnect the wires from the MOTOR.
[4] Remove the
Torx
SCREW from the WORM PULLEY ASSEMBLY.
[5] Move the TAB on the WORM PULLEY ASSEMBLY out.
[6] Remove the WORM PULLEY ASSEMBLY and MECHANISM BELT.
A091_4015BA
A091_4015BCA
MECHANISM BELT
FAN BELT