Symptom Possible Cause Action
The image is too light. The density level for the Auto
setting is set to LIGHT.
Adjust the setting for DENSITY
LEVEL (A) in the Utility mode.
(p. 5-22)
Otherwise, cancel the Auto
density setting, and then
manually select the desired
density setting. (p. 4-12)
The density level is set to
LIGHT.
Press the [Ö ] key, and then
select a darker copy density.
(p. 4-12)
Does the message TONER
EMPTY appear in the Display?
Change the Toner Cartridge
with a new one. (p. 6-6)
The paper is damp. Change the paper.
The image is too dark. The density level for the Auto
setting is set to DARK.
Adjust the setting for DENSITY
LEVEL (A) in the Utility mode.
(p. 5-22)
Otherwise, cancel the Auto
density setting, and then
manually select the desired
density setting. (p. 4-12)
The density level is set to
DARK.
Press the [ ] key, and then
select a lighter copy density.
(p. 4-12)
The Original Glass surface is
dirty.
Wipe the Original Glass clean
with a soft, dry cloth.
The original is not held tightly
against the Original Glass.
Place the original in position so
that it is held tightly against the
Original Glass.
The copy is blurry. The paper is damp. Change the paper.