KTI Networks KSD-103-B Series Switch User Manual


 
Use the provided 2P terminal plug for signal wiring and plug into the PF+/- contacts.
Normal PF+ and PF- contacts shorted
Relay Output
Indication
Alarm PF+ and PF- contacts open
Alarm Events:
Input power failure
Specific fiber port link down (To specify the fiber ports, use the DIP SW located on bottom.)
KSD-103-A
ON Enable broadcast storm protection
SW1
OFF Disable broadcast storm protection
ON Enable FX port link down alarm SW2
OFF Disable FX port link alarm
KSD-103-B
ON Enable broadcast storm protection
SW1
OFF Disable broadcast storm protection
ON Enable FX1 port link down alarm SW2
OFF Disable FX1 port link alarm
ON Enable FX2 port link down alarm SW3
OFF Disable FX2 port link alarm
Note: Be sure the voltage applied on PF+/- contacts is within the specification of 30VDC/1A max. or
120VAC/0.5A max.
15/20