Lantronix EDS-MD4 Server User Manual


 
6: Line and Tunnel Settings
EDS-MD User Guide 43
To Configure Tunnel Disconnect Mode Settings
Using Web Manager
To configure the Disconnect Mode for a specific tunnel, click Tunnel in the menu and select
Tunnel 1 -> Disconnect Mode.
Using the CLI
To enter the Tunnel 1 Disconnect command level: enable -> tunnel 1 -> disconnect
Using XML
Include in your file: <configgroup name=”tunnel disconnect” instance=”1”>
Modem Emulation
Some older equipment is designed to attach to a serial port and dial into a network with a modem.
This equipment uses AT commands to control the connection. For compatibility with these older
devices on modern networks, our product mimics the behavior of the modem.
Table 6-8 Tunnel Modem Emulation Settings
Modem Control Set whether Modem Control enables disconnect when the Modem Control pin
is not asserted on the Serial Line. Choices are:
Enabled
Disabled (default)
Timeout Enter the number of milliseconds a tunnel may be idle before disconnection.
The value of zero disables the idle timeout.
Flush Serial Data Set whether to flush the Serial Line when the Tunnel is disconnected. Choices
are:
Enabled
Disabled (default)
Tunnel Modem
Emulation Settings
Description
Echo Pluses Set whether the pluses will be echoed back during a “pause +++ pause”
escape sequence on the Serial Line. Choices are:
Enabled
Disabled (default)
Echo Commands Set whether characters read on the Serial Line will be echoed, while the Line
is in Modem Command Mode. Choices are:
Enabled
Disabled (default)
Verbose Response Set whether Modem Response Codes are sent out on the Serial Line.
Choices are:
Enabled
Disabled (default)
Tunnel Disconnect
Mode Settings
Description