Lathem DDC2 Clock User Manual


 
DDC2 / 4-RS Wiring Digital Display Wall Clock Guide Page 22
3-Wire Synchronous (115VAC)
H
M
BLU / WHT
Run
BRN / WHT
BLK
BLK
Correction
AC Return
115VAC
From
Master Cloc
k
To
Other Clocks
6
7
8
Clock will correct minutes hourly at HH:59 and
hour and minutes twice daily at 5:59.
Wiring applies to secondary wall clocks such as:
Lathem type SS Cincinnati D10 IBM 77 Series
Simplex 77 Series, 93-9, 91-9, 941-9, 943-9
Stromberg 3000
Set switches 1-5 of S1 as shown.
Indicates depressed side of switch
OPEN
1
2
3 4 5